Use case · Indoor Cellular & DAS

Fix poor cell signal inside your building.

Energy-efficient glass, concrete and steel keep the weather out, and the cell signal too. An indoor cellular system brings the major carriers inside.

TYPICAL SPACENew and renovated offices
WHAT HURTSCalls drop at the door
WHAT WE CHANGECarrier signal brought inside
Sound familiar?

What it looks like day to day.

A typical scenario based on the environments we work in, not a specific customer.

  • Calls drop when people walk in the door
  • Signal is fine by the windows and gone in the core
  • It depends on which carrier you have
  • People step outside to take calls
Signal fades past the windows compared with Every floor coveredBuilding section. Existing: outdoor macro signal reaches upper floors weakly; measured signal falls with each floor and there is no service below grade. Proposed: a donor antenna feeds a headend and riser that serve antennas on every floor, around -66 dBm throughout.AEXISTING CONDITIONSNTSGRADE ±0'MACROL4-88 dBmL3-94 dBmL2-101 dBmL1-108 dBmB1NO SVCEXISTING · MEASURED RSRP BY FLOORGAPSBPROPOSED DESIGNNTSGRADE ±0'MACROL4-66 dBmL3-67 dBmL2-68 dBmL1-66 dBmB1-67 dBmHEDONORRISERPROPOSED · DAS · RSRP BY FLOORALL FLOORSA — Signal fades past the windowsB — Every floor covered
Sheet A shows existing conditions; sheet B shows the proposed design. Illustrative, not to scale.
Why it happens

Modern buildings block cell signal by design.

Low-e glass and dense construction are great for energy efficiency and bad for cell signal. Wi-Fi calling helps some phones, but not every device, carrier or situation. An indoor system brings the carriers' signal inside and spreads it where people are.

What we do

How we fix it.

Indoor cellular (often called DAS) brings AT&T, Verizon and T-Mobile signal inside your building and spreads it where people are, so calls, texts and data just work.

  1. Measure what's there

    Check each carrier's signal inside and out.

  2. Design the system

    Antenna placement from your floor plans, with an onsite survey when the building calls for it.

  3. Coordinate with carriers

    Approvals and signal source handled for each carrier.

  4. Install and verify

    Confirm coverage floor by floor when the project calls for it.

Designs start from your floor plans and each carrier's signal. We survey on site when the building calls for it.

What changes

What's different after.

Calls that stay connected

Across floors, cores and interior rooms.

All major carriers

Not just whichever one someone happens to have.

A better building

Tenants and staff stop complaining about signal.

Is it a fit?

Where this works, and where something else fits better.

We recommend what solves the problem, even when it's a different solution.

A good fit for

  • New or renovated offices and clinics
  • Buildings with low-e glass or heavy concrete
  • Owners hearing signal complaints from tenants

Something else may fit better

For your IT or engineering team

Technical detail

The design decisions, the end-to-end path and how the result is tested.

Show

Indoor coverage can only be as good as the signal source, capacity, bands, and carrier participation feeding the system.

Design decisions

Design decisionWhat we need to understandHow we engineer it
Signal sourceMeasure donor cells, bands, quality, loading, and stability by carrier.Choose off-air, small-cell, or base-station sources from supported carrier conditions.
Service zonesMap occupied areas, cores, elevators, stairs, parking, and exterior transitions.Set coverage targets and antenna placement by space and construction loss.
Carrier pathIdentify carrier approvals, retransmission consent, equipment, and monitoring obligations.Build the program around supported participation rather than assumed compatibility.

The end-to-end path

  1. CARRIER SOURCEMacro donor · small cellSupported bands and capacity
  2. HEADENDFilter · amplify · combineSignal conditioning and monitoring
  3. DISTRIBUTIONFiber · coax · remotesLoss-managed RF transport
  4. INDOOR SERVICEAntennas · phones · devicesMeasured coverage and quality

Strong indoor power does not prove usable service. Signal quality, serving-cell behavior, capacity, uplink, and carrier acceptance must all be verified.

How the result is tested

  • Baseline test Capture pre-install carrier, band, cell, quality, and throughput data.
  • Coverage test Walk every occupied, critical, vertical, and below-grade zone.
  • Voice test Maintain calls through entrances, cores, elevators, and floor transitions.
  • Data test Measure uplink, downlink, latency, and stability by supported carrier.
  • Alarm test Verify headend, remote, donor, power, and transport monitoring.
  • Carrier test Complete the required carrier review and acceptance process.
Practical next step

Tell us where the phones stop working.

Share what's happening and where. We'll recommend the right fix and the next step, starting from your floor plans or site details.

Start your project